The Gnome Fuel Computer Test Set 1st Line

gnome1

The Gnome Fuel Computer First Line Test Set (GFC-FLTS) is a fault diagnostic tool for the Rolls-Royce Gnome engine fuel computer. The engine is deployed primarily on the Augusta Westland Sea king helicopter used nowadays primarily for search and rescue.

The test set is portable, requires no installation and acquires data for analysis via the Health Monitor Plug (HMP).


FEATURES

  • Portable and ruggedised
  • Cleared for connection & operation in flight
  • Simply connects to Health Monitor Plug on Gnome Fuel Computer
  • No installation required
  • Pre-programmed with standard Maintenance Manual Tests
  • Simultaneous recording of all 21 HMP signals
  • Record data to internal flash memory
  • Download to base station for operational analysis
  • Spreadsheet compatible plus graphical data display
  • Diagnose system faults without strip down
  • Reduce “No Fault Found” at 2nd Line
  • Diagnose intermittent Engine Freeze events
  • Simplified and faster Torque matching
  • Automatic capture of Knee Plots
  • 1 hour battery backup - no loss of data during power interruptions
  • Simple menu-driven user interface
  • Touch screen controls operable with gloves
  • Size: 33cm x 30cm x 9cm Weight: 7Kg
  • Operating Temperature: –26°C to +55 °C.


GENERAL INFORMATION

The GFC-FLTS consists of a Data Logger, Ground Station and various
ancillary parts.

The GFC-FLTS Data Recorder (DR) is a stand-alone data capture system
that can be used to simultaneously display and record all the analogue
signals that are available on the HMP. It can be used on board the aircraft
during ground running and flight.

The DR is packed in a padded carry case, complete with all the necessary
leads. It can be operated from the aircraft supply via the AUX Power
socket or from a dedicated 230VAC-28VDC power adapter.

The Ground Station consists of a notebook PC, complete with the
necessary software to help display the results in graphical format, a Bench
Charger part no. 7309-8, and auxiliary cables.

General Data

Manufacturers Part No. KD 7309
Manufacturers: Kenure Developments Limited
Weight: 7 Kilograms. (Data Recorder only)
Dimensions: Height 90mm. x Width 320m x Depth 300mm
(Data recorder excluding handles)

Environmental

The GFC-FLTS Data Recorder is designed to operate on board the aircraft as follows:-

ENVIRONMENT

TEMPERATURE RANGE

HUMIDITY

Operating

-26° C to +55° C

Up to 90%

Transportation and Storage

-40oC to +70oC

up to 100%

 
The GFC-FLTS Ground Station equipment is designed to operate in a sheltered environment as follows:

ENVIRONMENT

TEMPERATURE RANGE

HUMIDITY

Operating

+15° C to 25° C

30% to 50%

Transportation and Storage

-40oC to +71oC

up to 100%

Download Product Data Sheet

Transportation

The DR can be transported within the padded carry case, but additional packaging for some of the other items will be required.